Warning 2750: The input control is not linked to a data source
Symptom
While trying to print a label in BarTender Designer, Warning Message #2750 appears:
Environment
BarTender 2019 and above
Solution
This warning message occurs because there is at least one object on the Data Entry Form not linked to an object on the template. To resolve this warning, it will require connecting each input control object on the Data Entry Form to an object on the template by performing the following steps:
- Go into the Data Entry Form tab and locate the input control object the warning is referring to. In the example screenshot above, the problematic input control is labeled "Text Input Box 1".
- Open the Properties dialog for the input control object on the Data Entry Form by right click on it:
- Click on Linked Data Source and then select the data source to link:
- Close the properties dialog and repeat these steps until all input controls are connected to an object on the template
Additional resources
- For more information on Data Entry Form, please refer to Creating data entry forms and Using Data Entry at Print Time